Web page revised 1.1.26
What is the Review Process?
Certain wireless communication facilities such as new towers in some resource and industrial areas and collocates that are not exempt from SEPA are subject to a Type II review process, which requires a ministerial decision by the Responsible official. In making the decision, the Responsible Official must determine if the proposed facility meets the requirements of the applicable sections of the Clark County Code (CCC). This decision is made after reviewing the proposal and considering written comments received from the public. The Responsible Official will approve, approve with conditions, or deny the application. This decision may be appealed to the county Hearing Examiner.
Is a pre-application conference required?
A pre-application conference is required before submitting a Type II application. The requirement for a conference may be waived if the Planning Director determines that the proposal is relatively simple. A waiver requires the applicant to submit a completed Pre-Application Review Waiver Request Form and fee.
What is the application process?
See Type II Submittal Process (CCC 40.510.020).
All land use reviews are completed online.
Follow the Land Use Application Submittal Process and these instructions on how to apply online.
Contact planningapps@clark.wa.gov with questions on how to apply.
After the Preliminary Site Plan is approved, what is next?
After receiving approval of the preliminary site plan, the applicant may submit the engineering constructions and building plans for review. A final site plan, which reflects any applicable conditions of approval, must be submitted with the engineering construction plans for approval.
How long do I have before I must begin construction of the development?
A preliminary site plan approval shall be valid for a period of seven years after approval, during which time an application for a building permit for the subject development must be submitted. This time limit may be extended where there is an approved phased development or separate development agreements have been approved. See Clark County Code, Section 40.500.010(B) for more details.
See Engineering Construction Plan Review for further information about the final engineering plan review process.
Submittal Requirements
The following list identifies information to be included with the application. The Pre-Application Conference Report will indicate any additional/exempted submittal requirements.
- Cover sheet and table of contents - Each submittal packet shall contain a cover sheet that contains the project name and applicant’s name, address, email address, and phone number. A table of contents to provide assistance in locating the various requirements the PDF files shall be named/labeled to follow the cover sheet.
- Application form - The application form shall be completed and original signed in ink by the applicant.
- Application fee - The required fee shall accompany the application.
- Pre-Application Conference Report - A copy of the Pre-Application Conference Report must be submitted.
- GIS Developer’s packet - A copy of the GIS Developer’s Packet shall be submitted with the application. Applicants can order a GIS Developer's Packet with a credit card online. For more information, contact GIS at 564.397.4082 or themapstore@clark.wa.gov.
- Narrative - A written narrative shall be submitted that addresses the following:
- Collocations
- How the application meets or exceeds each of the applicable approval criteria and standards
- How the proposed plan meets the minimum area and dimensions of the base zone
- How the issues identified in the pre-application conference have been addressed, and generally, how services will be provided to the site
- A comprehensive description of the existing or proposed facility including the technical reasons for the design and configuration of the facility, design and dimensional information, and anticipated coverage of the facility
- If camouflage technology is proposed, the applicant shall provide a complete description of the suggested camouflage, including style and materials to be used, a photographic depiction of the proposed facility, and a maintenance plan detailing provisions for the continued effectiveness of the suggested camouflage for the life of the facility
- The proposed frequency of trips the proposal could be expected to generate
- New support structures and towers
- How the application meets or exceeds each of the applicable approval criteria and standards
- How the proposed plan meets the minimum area and dimensions of the base zone
- How the issues identified in the pre-application conference have been addressed, and generally, how services will be provided to the site
- A comprehensive description of the existing or proposed facility including the technical reasons for the design and configuration of the facility, design and dimensional information, anticipated coverage of the facility and the ability to accommodate future co-location opportunities
- If camouflage technology is proposed, the applicant shall provide a complete description of the suggested camouflage, including style and materials to be used, a photographic depiction of the proposed facility, and a maintenance plan detailing provisions for the continued effectiveness of the suggested camouflage for the life of the facility
- An analysis of the proposal area and discussion of factors influencing the decision to target the proposed location. Such analysis shall include the good faith efforts and measures taken to secure a higher priority location, how and why such efforts were unsuccessful, and how and why the proposed site is essential to meet service demands for the geographic service area
- An analysis of existing WCFs within the intended service area, describing the status of collocation opportunities at these sites
- The proposed frequency of trips the proposal could be expected to generate
- Collocations
- Authorization to use site and support structure - Documentation that establishes the applicant’s right to use the site shall be provided at the time of application by a copy of the proposed lease agreement, easement agreement, license agreement or letter of authorization to use the facility from the owner of the support structure.
- Legal lot determination information - The preliminary site plan shall encompass the entire area of the legal lot(s) involved in the site plan, designate the proposed use (i.e., lots, tracts, easements, dedications) for all land contained within the plan, and include any boundary line adjustments to be completed prior to final site plan approval. In order to demonstrate that the subject lot(s) has been created legally, one of the following must be submitted:
- Current owner's deed if a lot determination is not required, as specified in the Pre-Application Conference Report
- Prior county short plat, subdivision, lot determination or other written approvals, if any, in which the parcel was formally created or determined to be a legal lot
- Submit a sales or transfer deed history dating back to 1969, to include copies of recorded deeds and/or contracts verifying the date of creation of the parcel in chronological order with each deed identified with the Assessor’s lot number
- Proposed site plan - The proposed plan shall be drawn to a minimum engineer’s scale of 1” = 200’. The following information shall be clearly depicted on the proposed site plan:
- General information
- Applicant’s name, mailing address and phone number
- Owner’s name and mailing address
- Contact person’s name, mailing address, and phone number
- North arrow oriented to the top, left or right of page, scale, and date
- Proposed name of project
- Vicinity map covering ¼ mile radius from the development site (not required for rural area plans)
- Area of the site in acres or square feet
- Collocations
- Existing conditions
- Show the entire parcel, drawn to scale, with property lines, north arrow (orientated to the top, left or right), footprint of existing structures and driveways, parking spaces, abutting streets (name, centerline, curb and sidewalk), and existing fire hydrants
- Elevation plans showing the existing antennae and the height of each as well as any lightning rods (as applicable)
- Proposed improvements
- Show the location of all proposed structures, driveways and roads, easements. number and layout of proposed parking spaces; (as applicable) and proposed location of fire hydrants
- Landscape plan if landscaping is proposed
- Elevation plans of proposed site and facility changes
- Existing conditions
- New support towers and structures:
- Existing conditions
- Environmental conditions on and within 100 feet of the site must be shown.
For purposes of being determined fully complete, only those existing conditions that are shown on the GIS map, known by the applicant or are discussed in the pre-application summary must be included on the proposed plan.- Topography at 2-foot contour intervals, or other intervals if not available from a public source, see GIS Packet
- Watercourses, streams, rivers, etc., see GIS Packet
- Center of stream surveyed for all on-site water- courses with Professional Land Surveyor Stamp and signature
- Areas prone to flooding
- FEMA designated floodplains, flood fringe, or floodway, see GIS Packet
- Designated shoreline areas, see GIS Packet
- Water bodies and known wetlands, see GIS Packet
- Wetland delineation, see Pre-application Report
- Unstable slopes and landslide hazard areas, see GIS Packet
- Significant wildlife habitat or vegetation, see GIS Packet
- Significant historic sites, see GIS Packet and Pre-Application Report
- Land use and transportation
- Layout, square footage and dimensions of all parcels
- Location(s) of any existing building(s) on the site and use
- Location and width of existing easements for access, drainage, utilities, etc.
- Name, location and width of existing rights-of-way
- Centerline and right-of-way radius of existing roadways that abut the site
- Name, location, width and surfacing materials, such as gravel, asphalt or concrete, of roadways and easements, private and public
- Location of existing driveways and those driveway across the street to include distance between driveways and roadways edge to edge
- Location and width of existing pedestrian and bicycle facilities on and within 100 feet of the site
- Transit routes and stops within 600 feet of the development site, see GIS Packet
- Water and Sewer
- Location and direction to nearest fire hydrant, see GIS Packet
- Location of existing sewage disposal systems and wells on the site
- Location of existing sewage disposal systems and wells within 100 feet of the site as available from Public Health
- Proposed improvements
- Environmental
- Wetland, stream, steep bank buffer areas/protected areas
- Planned enhancement areas
- Environmental
- Land use and transportation
- The configuration and dimensions of the project boundaries, proposed lots and tracts, including proposed park, open space, and or drainage tracts or easements
- Dimensions of all proposed easements
- Location of any existing buildings to remain on the site to include approximate square footage and dimensions from property lines. For all structures include the number of stories, construction type, such as metal, wood, concrete block, etc., and proposed uses
- Location and width of all road rights-of-way
- Location, width from curb to curb and surface material of all proposed roadways, private and public, provided by drawing or note and typical cross- section from county road standards
- Location of all road segments in excess of 15 percent grade that are either on the site or within 500 feet of the site which are being proposed for site access
- Location, width and surface material of off-site roads which will provide access to the site within 500 feet of the site
- Location and width of proposed driveways for corner lots and driveways where site distance standards cannot be met
- Site distance triangles where site distance standards can not be met
- Location and width of proposed easements for access, drainage, utilities, etc. provided by drawing or note
- Layout of proposed structures including square feet
- Elevation plans showing the proposed tower and antennae, and the height of each as well as any lightning rods, as applicable
- Location, dimensions and number of off-street parking and loading areas
- Distance between existing and proposed structures and associated facilities, and nearest residence on adjacent properties
- Landscaping
- Landscape and screening plans for new support towers and structures and urban area arterial and collector roadways must be submitted, to include:
- Location, number, species, size at planting, and spacing of proposed plant material
- Location, number, species and size of existing landscape material to be removed and/or retained
- Location, type (such as sod, groundcover or shrub mass) and area (in terms of square fee and percentage of site) of all soft landscaped areas and buffers
- Location, height and materials of fences, buffers, berms, walls and other methods of screening
- Landscaping and screening Installation procedures and maintenance plans
- Landscape and screening plans for new support towers and structures and urban area arterial and collector roadways must be submitted, to include:
- General information
- Aerial photograph - For new support towers and structures only. An aerial photograph, which clearly indicates the location of the proposed facility in relation to:
- Significant features within 1320 feet including, but not limited to, existing and/or proposed site structures, public rights-of way, residential developments, adjacent land uses, and properties used for public purposes
- Governmental jurisdictional boundaries within 500 feet of the proposal boundaries
- Cliffs, snags, talus, Oregon white oak woodlands, urban natural open space, waterfowl habitat and bald eagle foraging areas within a 1000 feet as defined by the Department of Fish and Wildlife as Priority Habitats and Species areas subject to CCC 40.440
- Photographic analysis - For new support towers and structures only. A photographic analysis of the proposed site, including a representation of existing conditions and photographic simulations depicting views of any new support structures or towers must be submitted.
- Soil analysis report, if applicable
- Preliminary stormwater design report, if applicable
- Proposed stormwater plan, if applicable
- Project engineer statement of completeness and feasibility - The project engineer shall include a statement that all information required by CCC 40.386 Stormwater and Erosion Control Ordinance is included in the preliminary stormwater plan and that the proposed stormwater facilities are feasible.
- State environmental review - A State Environmental Policy Act Environmental Checklist must be completed, original signed in ink, and submitted. Handout is available at the Permit Center.
- Proof of submitting an archaeological pre-determination to the state, if applicable. Predetermination reports and archaeology surveys, if required, must be reviewed by the Washington State Department of Archaeology and Historic Preservation (DAHP). Proof must be provided indicating the predetermination and/or survey have been submitted to DAHP for review. Proof can be via an email confirmation or other conclusive method of proof that DAHP has received the site-specific document for review.
- Public Health review evaluation letter - A Clark County Public Health Project Review Evaluation Letter must be submitted per the Pre-Application Conference Report.
- Covenants or restrictions - All existing covenants or restrictions and/or easements that apply to the property must be submitted, available from a title company.
- Associated applications - Applications associated with the preliminary plat, such as archaeological, critical aquifer recharge areas (CARA), floodplain, forestry, geo-hazard, habitat, shoreline, wetland, road modification, variances, etc., must be submitted with this application. See Pre-Application Conference Report.
- Engineering report - For new support towers, a report stamped, dated and signed by a licensed professional engineer registered in the state of Washington demonstrating the following:
- The facility complies with all requirements of the Uniform Building Code
- The structural capability of the facility will support co-located antennas, if applicable
- The facility complies with all applicable standards of the FAA and FCC, including RF energy standards
- The basis for the calculation of capacities
- For collocations an engineering analysis of the existing tower for the new imposed loads to tower
- FAA Compliance - For new towers, evidence of compliance with Federal Aviation Association (FAA) requirements must be submitted with the application.
Fee schedule
The following fees are required to be paid when the application is submitted.
Land use application submittal: $1,069
Wetland/habitat application submittal: $233
Issuance: $94
The following fees are required to be paid when the application has been deemed Fully Complete.
Planning: $4,275
Issuance: $94
Engineering: $601
Issuance: $94
SEPA review: $2,174
Fire Marshal Review, if applicable: $434
A Legal Lot Determination may be required if a previous legal review has not been completed.
Reference
Clark County Code 40.520.040 Site Plan Review and 40.260.250 Wireless Communication Facilities